Descriere
Variable speed starters, Part group reference (e.g. DIL): DE1, Rated operational voltage: Ue = 230 V AC, 1-phase, 240 V AC, single-phase, Output voltage with Ve: U2 = 230 V AC, 3-phase, 240 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 200 (-10%) - 240 (+10%) V, Rated operational current At 150% overload: Ie = 4.3 A, Note: Rated operational current at an operating frequency of 16 kHz and an ambient air temperature of +50 °C, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz , Overload cycle for 60 s every 600 s, at 230 V, 50 Hz, Assigned motor rating 150 % Overload: P = 0.75 kW, 150 % Overload: IM = 3.2 A, Assigned motor rating Note: at 220 - 240 V, 60 Hz, Assigned motor rating 150 % Overload: P = 1 HP, Assigned motor rating 150 % Overload: IM = 3.2 A, Degree of Protection: IP20/NEMA 0, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, Frame size: FS1, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1
Specificatii
| Electrical | |
| Mains voltage | 200 |
| Mains frequency | 50/60 Hz |
| Max. output voltage | 250 |
| Nominal output current I2N | 4.3 |
| Power consumption | 32 |
| Relative symmetric net voltage tolerance | 10 |
| Connection | |
| Number of phases input | 1 |
| Number of phases output | 3 |
| Number of analogue outputs | 0 |
| Number of analogue inputs | 1 |
| Number of digital outputs | 0 |
| Number of digital inputs | 4 |
| With PC connection | Yes |
| Other | |
| Max. output frequency | 300 |
| Relative symmetric net frequency tolerance | 10 |
| Performance | |
| Max. output at quadratic load at rated output voltage | 0.75 |
| Max. output at linear load at rated output voltage | 0.75 |
| Model/type | |
| With control element | No |
| Type of converter | U converter |
| Application | |
| Application in industrial area permitted | Yes |
| Application in domestic- and commercial area permitted | Yes |
| Communication | |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | Yes |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | Yes |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for BACnet | No |
| Supporting protocol for other bus systems | Yes |
| Number of HW-interfaces industrial Ethernet | 0 |
| Number of interfaces PROFINET | 0 |
| Number of HW-interfaces RS-232 | 0 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-485 | 1 |
| Number of HW-interfaces serial TTY | 0 |
| Number of HW-interfaces USB | 0 |
| Number of HW-interfaces parallel | 0 |
| Number of HW-interfaces other | 0 |
| With optical interface | No |
| Options | |
| Integrated breaking resistance | No |
| Setting/control | |
| 4-quadrant operation possible | No |
| Protection | |
| Degree of protection (IP) | IP20 |
| Degree of protection (NEMA) | Other |
| Measurements | |
| Height | 230 |
| Width | 45 |
| Depth | 169 |
| Package 1 | |
| volume | 0,002798 |
| weight | 1,198 |
| length | 0,185 |
| width | 0,055 |
| qmax | 1 |
| qmin | 1 |
| um | CS |
| gtin | 4015081718221 |
| Dimensions of product | |
| Volume | 0,001749 |
| Weight | 1,06 |
| Length | 0,169 |
| Width | 0,045 |
| Depth | 0,23 |