Descriere
Function element, Connection to SmartWire-DT: yes, For use with: DILM(C)7… - DILM(C)32…, DILM38…, DILA…, DILMP20…, DILMP32…, DILMP45…, MSC-D(E)-...(24VDC)
Specificatii
Electrical | |
Supply voltage AC 50 Hz | 0 |
Supply voltage AC 60 Hz | 0 |
Supply voltage DC | 15 |
Voltage type (supply voltage) | DC |
Input current at signal 1 | 3 |
Permitted voltage at input | 15 |
Type of voltage (input voltage) | DC |
Output current | 0.5 |
Permitted voltage at output | 20.4 |
Type of output voltage | DC |
Connection | |
Number of digital inputs | 2 |
Number of digital outputs | 1 |
Short-circuit protection, outputs available | No |
Type of electric connection | Spring clamp connection |
Fieldbus connection over separate bus coupler possible | Yes |
Options | |
Digital inputs configurable | No |
Digital outputs configurable | No |
Radio standard Bluetooth | No |
Radio standard WLAN 802.11 | No |
Radio standard GPRS | No |
Radio standard GSM | No |
Mobile communications standard 3G (UMTS) | No |
IO link master | No |
System accessory | Yes |
Rack-assembly possible | No |
Model/type | |
Type of digital output | None |
Communication | |
Number of HW-interfaces industrial Ethernet | 0 |
Number of interfaces PROFINET | 0 |
Number of HW-interfaces RS-232 | 0 |
Number of HW-interfaces RS-422 | 0 |
Number of HW-interfaces RS-485 | 0 |
Number of HW-interfaces serial TTY | 0 |
Number of HW-interfaces parallel | 0 |
Number of HW-interfaces wireless | 0 |
Number of HW-interfaces USB | 0 |
Number of HW-interfaces other | 1 |
With optical interface | No |
Supporting protocol for EtherCAT | No |
Supporting protocol for TCP/IP | No |
Supporting protocol for PROFIBUS | No |
Supporting protocol for CAN | No |
Supporting protocol for INTERBUS | No |
Supporting protocol for ASI | No |
Supporting protocol for KNX | No |
Supporting protocol for Modbus | No |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for SUCONET | No |
Supporting protocol for LON | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for SERCOS | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for other bus systems | Yes |
Protection | |
Degree of protection (IP) | IP20 |
Explosion safety category for gas | None |
Explosion safety category for dust | None |
Certified for UL hazardous location group E (metal dusts) | No |
Other | |
Time delay at signal change | 10 |
Appendant operation agent (Ex ia) | No |
Appendant operation agent (Ex ib) | No |
Mounting/installation | |
Suitable for rail mounting | No |
Wall mounting/direct mounting | No |
Front built-in possible | No |
Application | |
Suitable for safety functions | No |
Approval/certification | |
SIL according to IEC 61508 | None |
Certified for UL hazardous location class I | No |
Certified for UL hazardous location class II | No |
Certified for UL hazardous location class III | No |
Certified for UL hazardous location division 1 | No |
Certified for UL hazardous location division 2 | No |
Certified for UL hazardous location group A (acetylene) | No |
Certified for UL hazardous location group B (hydrogen) | No |
Certified for UL hazardous location group C (ethylene) | No |
Certified for UL hazardous location group D (propane) | No |
Certified for UL hazardous location group F (carbonaceous dusts) | No |
Certified for UL hazardous location group G (non-conductive dusts) | No |
Performance | |
Performance level according to EN ISO 13849-1 | None |
Measurements | |
Width | 45 |
Height | 38 |
Depth | 72 |